Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.881
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(5): 13, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713484

RESUMEN

Purpose: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. Methods: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. Results: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. Conclusions: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.


Asunto(s)
Cadáver , Gonioscopía , Presión Intraocular , Iris , Terapia por Láser , Trabeculectomía , Humanos , Presión Intraocular/fisiología , Terapia por Láser/métodos , Iris/cirugía , Trabeculectomía/métodos , Tonometría Ocular , Anciano , Iridectomía/métodos , Femenino , Masculino , Anciano de 80 o más Años
2.
Trials ; 25(1): 300, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702810

RESUMEN

BACKGROUND: Minimally invasive glaucoma surgery (MIGS) is a new class of surgeries, which combines moderate to high success rates and a high safety profile. Bent Ab interno Needle Goniotomy (BANG) and Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) are two low-cost MIGS procedures that communicate the anterior chamber to Schlemm's canal. Most of the available publications on MIGS are either case series or retrospective studies, with different study protocols. The aim of this manuscript is to describe a randomized clinical trial (RCT) protocol to compare the long-term intraocular pressure (IOP) control and the safety of both procedures in eyes with primary open-angle glaucoma. METHODS: This is a parallel, double-arm, single-masked RCT that includes pseudophakic primary open-angle glaucoma (POAG) eyes. After inclusion criteria, medications will be washed out to verify baseline IOP before surgery. Patients will be randomized to BANG or GATT using a sealed envelope. Follow-up visits will be 1, 7, 15, 30, 60, 90, 180, 330 and 360 days after surgery. On PO330, a new medication washout will be done. The main outcome is the IOP reduction following the procedures. Complimentary evaluation of functional and structural parameters, safety, and quality of life will be done after 30, 90, 180, and 360 days. DISCUSSION: Our study was designed to compare the long-term efficacy and safety of two low-cost MIGS. Most of the published studies on this subject are case series or retrospective cohorts, with different study protocols, which included different types and severities of glaucomas, combined with cataract extraction. Our study only included mild to moderate POAG eyes, with previous successful cataract extraction. Moreover, it provides a standardized protocol that could be replicated in future studies investigating various types of MIGS. This would allow comparison between different techniques in terms of efficacy, safety, and patients' quality of life. TRIAL REGISTRATION: Retrospectively registered at the Registro Brasileiro de Ensaios Clínicos (ReBEC) platform RBR-268ms5y . Registered on July 29, 2023. The study was approved by the Ethics Committee of the University of Campinas, Brazil.


Asunto(s)
Glaucoma de Ángulo Abierto , Gonioscopía , Presión Intraocular , Ensayos Clínicos Controlados Aleatorios como Asunto , Trabeculectomía , Humanos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Trabeculectomía/métodos , Trabeculectomía/instrumentación , Resultado del Tratamiento , Método Simple Ciego , Masculino , Femenino , Factores de Tiempo , Persona de Mediana Edad , Agujas , Anciano , Adulto
3.
Zhonghua Yan Ke Za Zhi ; 60(5): 399-402, 2024 May 11.
Artículo en Chino | MEDLINE | ID: mdl-38706076

RESUMEN

The advent of minimally invasive glaucoma surgery (MIGS) has broadened the therapeutic options for managing glaucoma. In recent years, MIGS procedures targeting the trabecular meshwork-Schlemm's canal aqueous outflow resistance site have garnered significant attention. This focus has extended to the pathophysiological changes occurring within the aqueous outflow pathway. However, questions persist regarding the efficacy of near-peripheral or peripheral trabeculotomy in achieving the anticipated reduction of outflow resistance and the suitability of MIGS surgery for patients with primary open-angle glaucoma. By integrating clinical experience with pertinent clinical research, this paper advocates for a reevaluation of MIGS procedures to aid clinicians in making informed decisions regarding various glaucoma surgical interventions.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos , Malla Trabecular , Trabeculectomía , Humanos , Malla Trabecular/cirugía , Trabeculectomía/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma/cirugía , Humor Acuoso
4.
Zhonghua Yan Ke Za Zhi ; 60(5): 408-415, 2024 May 11.
Artículo en Chino | MEDLINE | ID: mdl-38706078

RESUMEN

Objective: To compare the medium-term therapeutic effects of Kahook Dual Blade (KDB) goniotomy and Trabectome surgery in the treatment of patients with primary open-angle glaucoma (POAG). Methods: This study was a non-randomized prospective interventional controlled clinical study. POAG patients who underwent KDB goniotomy or Trabectome surgery at Beijing Tongren Hospital from May 2017 to April 2022 were enrolled. The definition of successful surgery was postoperative average intraocular pressure (IOP)≤21 mmHg (1 mmHg=0.133 kPa) and IOP decrease≥20%. Follow-up visits were conducted on the 1st day, 1st week, 1st, 3rd and 6th month after surgery. The IOP value, the number of IOP-lowering medications, the proportion of surgical success (average IOP≤21 mmHg at 6 months), and complications were evaluated. Statistical methods included independent sample t-test, Mann-Whitney rank sum test, χ2 test, repeated measures two-factor analysis of variance, Bonferroni, Friedman M test, Wilcoxon, and Log-rank. The Kaplan-Meier method was used to calculate the cumulative success rate of each group. Results: Seventeen male patients (17 eyes) and 10 female patients (10 eyes) were included. The mean age was (39.9±17.7) years old. There were 11 patients in the KDB group and 16 patients in the Trabectome group. There was no significant difference in clinical baseline conditions between the two groups (P>0.05). The IOPs in the KDB and Trabectome groups at postoperative 1 week [(16.6±6.3) and (16.4±4.1) mmHg) and 6 months [(17.8±5.3) and (19.9±4.4) mmHg) were lower than those before surgery [(25.1±9.3) and (27.4±9.1) mmHg) (all P<0.05). There was no significant difference in the overall IOP between groups (P>0.05). The IOP reduction rates in the KDB and Trabectome groups were 23.4% and 19.0%, with no significant difference (P=0.674). The numbers of IOP-lowering medications used in the KDB and Trabectome groups at 3 months [2.0 (1.0, 4.0) and 2.0 (1.0, 2.3)] and 6 months [2.0 (0.0, 4.0) and 2.0 (1.0, 3.0)] after surgery were not significantly different from those before surgery [4.0 (2.0, 4.0) and 3.0 (2.0, 4.0)] (both P>0.05). There was no statistical significance in the overall number of IOP-lowering medications used between the two groups (P>0.05). There was also no statistically significant difference in the proportion of patients with an IOP decrease of≥20% and the proportion of patients whose mean postoperative IOP was≤21 mmHg (all P>0.05). The proportions of IOP≤21 mmHg in the KDB group and the Trabectome group at 6 months after surgery were 81.8% and 68.8% (P>0.05). Serious intraoperative or postoperative complications occurred in neither group. Conclusions: Both KDB trabeculotomy and Trabectome surgery can effectively reduce IOP and have a good safety profile in treating POAG, with the same number of IOP-lowering medications.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Trabeculectomía , Humanos , Glaucoma de Ángulo Abierto/cirugía , Trabeculectomía/métodos , Estudios Prospectivos , Resultado del Tratamiento , Femenino , Masculino , Persona de Mediana Edad
5.
Int Ophthalmol ; 44(1): 201, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38664258

RESUMEN

AIM: To retrospectively evaluate the effectiveness and reliability of selective laser trabeculoplasty (SLT) treatment in juvenile open angle glaucoma (JOAG) cases. MATERIAL AND METHOD: The 46 eyes of 28 cases that had undergone SLT for JOAG and had a follow-up of at least one month were included in the study. The pre-SLT, month 1, month 6, year 1, year 2, and final follow-up intraocular pressure (IOP); the number of drugs before and after the SLT procedure; and the complications caused by the SLT were recorded. An IOP below 21 mmHg without any additional medication or glaucoma surgery and an IOP decrease of 20% or more compared to the baseline were considered successful. RESULTS: There were 18 females and 10 males with a mean age of 17.52 ± 2.7 (13-22) years. The cases were followed-up for a mean duration of 39 (5-59) months. The mean IOP was 23.93 ± 0.52 mmHg before SLT and decreased to 17.15 ± 0.57 mmHg at month 1 after the procedure, 17.17 ± 0.52 mmHg at month 6, 18.02 ± 0.77 mmHg at year 1, 18.12 ± 0.48 mmHg at year 2, and 20.93 ± 0.69 mmHg at the final follow-up. The post-SLT IOP measurements at all times were found to be significantly lower than the pre-SLT values (p < 0.001). The mean number of drugs was 1.5 before the SLT and 0.59 afterwards (p < 0.001). The most common complications after SLT were anterior chamber inflammation in 29 cases (63.04%), hyperemia in 20 (43.40%) cases (4.34%), an early period IOP increase of 5 mmHg or more in 11 cases (23.91%), and mild ocular pain in 2 cases (4.34%). CONCLUSION: SLT is an effective and reliable method for JOAG treatment.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Terapia por Láser , Trabeculectomía , Humanos , Trabeculectomía/métodos , Masculino , Femenino , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Estudios Retrospectivos , Adolescente , Terapia por Láser/métodos , Estudios de Seguimiento , Adulto Joven , Resultado del Tratamiento , Tonometría Ocular , Agudeza Visual , Reproducibilidad de los Resultados
6.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38626932

RESUMEN

BACKGROUND/AIMS: This study aimed to investigate and compare the efficacy and safety of first-line and second-line selective laser trabeculoplasty (SLT) in Japanese patients with normal-tension glaucoma (NTG). METHODS: 100 patients with NTG were enrolled in this study. Patients were treated with SLT as a first-line or second-line treatment for NTG. Main outcome measures were intraocular pressure (IOP) reduction rate, outflow pressure improvement rate (ΔOP), success rate at 1 year and complications. Success was defined as ΔOP≥20% (criterion A) or an IOP reduction ≥20% (criterion B) without additional IOP-lowering eye-drops, repeat SLT or additional glaucoma surgeries. The incidence of transient IOP spike (>5 mm Hg from the pretreatment IOP), conjunctival hyperaemia, inflammation in the anterior chamber and visual impairment due to SLT were assessed. RESULTS: A total of 99 patients (99 eyes) were initially enrolled in this study, including 74 eyes assigned to the first-line SLT group and 25 eyes to the second-line SLT group. The mean IOP of 16.3±2.1 mm Hg before SLT decreased by 17.1%±9.5% to 13.4±1.9 mm Hg at 12 months after SLT in the first-line group (p<0.001), and the mean IOP of 15.4±1.5 mm Hg before SLT decreased by 12.7%±9.7% to 13.2±2.0 mm Hg at 12 months after SLT (p=0.005) in the second-line group. Both groups showed significant reductions in IOP. Higher pre-SLT IOP and thinner central corneal thickness were associated with greater IOP reduction. The success rate at 1 year was higher in the first-line compared with the second-line group, with lower pretreatment IOP and the use of IOP-lowering medication before SLT being associated with treatment failure. Most post-treatment complications were minor and transient. CONCLUSIONS: SLT may be an effective and safe treatment option for NTG, as either a first-line or second-line treatment. TRIAL REGISTRATION NUMBER: The study was registered in the UMIN-CTR (UMIN Test ID: UMIN R000044059).


Asunto(s)
Glaucoma , Láseres de Estado Sólido , Glaucoma de Baja Tensión , Hipotensión Ocular , Trabeculectomía , Humanos , Trabeculectomía/efectos adversos , Presión Intraocular , Glaucoma de Baja Tensión/cirugía , Glaucoma/cirugía , Hipotensión Ocular/cirugía , Cámara Anterior , Láseres de Estado Sólido/uso terapéutico , Estudios de Cohortes
7.
Lasers Surg Med ; 56(4): 382-391, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38570914

RESUMEN

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Asunto(s)
Glaucoma de Ángulo Abierto , Trabeculectomía , Humanos , Trabeculectomía/métodos , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Rayos Láser , Cadáver
8.
BMC Ophthalmol ; 24(1): 157, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594720

RESUMEN

BACKGROUND: Aniridia is a rare eye disorder with a high incidence of glaucoma, and surgical intervention is often needed to control the intraocular pressure (IOP). Here, we reported a case of illuminated microcatheter-assisted circumferential trabeculotomy (MAT) performed on an aniridic glaucoma patient following a previous failed angle surgery. The surgical procedures for aniridic glaucoma were also reviewed. CASE PRESENTATION: A 21-year-old man, diagnosed with aniridic glaucoma, came to our hospital consulting for the poor control of left eye's IOP despite receiving goniotomy surgery 3 years ago. The IOP was 26 mmHg with maximum topical antiglaucoma eyedrops. The central cornea was opaque and the majority of iris was absent. The gonioscopy and ultrasound biomicroscopy (UBM) demonstrated that 360° anterior chamber angle was closed. The whole exome sequencing of peripheral blood confirmed a 13.39 Mb copy number loss at chromosome 11p15.1p13, containing PAX6 and WT1 gene. The 360° MAT surgery was performed on his left eye. At 1-year follow-up, the IOP was 19mmHg with 2 kinds of topical antiglaucoma medications, and the postoperative UBM demonstrated the successful incision of the anterior chamber angle. CONCLUSIONS: The case presented here exhibited a case of aniridic glaucoma treated by MAT surgery. The MAT surgery may be an effective option for IOP control in aniridic glaucoma patients following a previous failed angle surgery.


Asunto(s)
Aniridia , Glaucoma , Trabeculectomía , Humanos , Masculino , Adulto Joven , Estudios de Seguimiento , Glaucoma/diagnóstico , Glaucoma/cirugía , Gonioscopía , Presión Intraocular , Factor de Transcripción PAX6 , Estudios Retrospectivos , Trabeculectomía/métodos , Resultado del Tratamiento
9.
Indian J Ophthalmol ; 72(Suppl 3): S345-S353, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648451

RESUMEN

Age is an important risk factor for both glaucoma and cataract. As global life expectancy continues to rise, the prevalence of concomitant open-angle glaucoma (OAG) and cataracts is increasing. Currently, there is a lack of definitive consensus on the optimal management approach for such individuals. Conventionally, trabeculectomy (Trab) in combination with phacoemulsification is the preferred method. Recent developments in microinvasive glaucoma surgery (MIGS), which offer similar results with fewer complications, provide a new possible approach to this condition. This study aimed to assess the current knowledge of combination surgery in patients with cataract and OAG to provide a comprehensive understanding and help its implementation in clinical settings. A comprehensive systematic search was conducted in May 2021 on five databases (MEDLINE, Embase, SCOPUS, Proquest, EBSCO, and Cochrane Library). The results were filtered for English and human studies but not publication year. All studies published up to May 2021 were reviewed. Newcastle-Ottawa Scale and PEDro scale were used to screen studies for risk of bias where appropriate. Four studies satisfied the inclusion criteria and were subsequently added in this review. Study designs consisted of one RCT and three descriptive studies. Appropriate assessment tools were used; these studies demonstrated moderate to good quality. Postoperative mean IOP, IOP reduction, and qualified success rates were comparable in the Phaco-MIGS (Phaco-endoscopic cyclophotocoagulation (ECP), Phaco-ab interno trabeculectomy (AIT)) and Phaco-Trab group. Severe complication was reported only in the latter. Phaco-MIGS (in particular, trabectome) shows excellent promise as an option for individuals with OAG and concomitant cataract; further research through RCT is required to validate these findings.


Asunto(s)
Catarata , Glaucoma de Ángulo Abierto , Presión Intraocular , Trabeculectomía , Humanos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/complicaciones , Trabeculectomía/métodos , Catarata/complicaciones , Presión Intraocular/fisiología , Agudeza Visual
11.
Klin Monbl Augenheilkd ; 241(4): 361-366, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38653303

RESUMEN

The PRESERFLO™ MicroShunt (MP; Santen Inc., Osaka, Japan) is a minimally invasive bleb surgery (MIBS) manufactured to treat primary open-angle glaucoma (POAG), with lower postoperative adverse effects than with conventional filtering surgeries. We describe here the case study of a 58-year-old woman who presented with bilateral severe myopia with bilateral advanced POAG and unreached target pressure under quadritherapy, who was successfully managed by PM surgery. A review of the literature completes our observation. At presentation, the patient had a spherical equivalent of - 7.50 RE and - 7.75 LE with an IOP of 22 mmHg right and left eye (RLE) under quadritherapy, and with severe bilateral visual field loss, including scotomas within the central 5°. The patient presented with systemic hypertension treated with an antihypertensive drug. Two selective laser trabeculoplasties (SLT), performed 3 months apart, were first tried on the LE, without any change in IOP at 2 months. After considering the high risk of postoperative complications, a PM operation was proposed, with a targeted IOP in the mid-fifteens RLE. The patient's eyes underwent PM surgery with mitomycin C (MMC) MMC0.2 mg/mL for 3 minutes without any complications. The LE required 2 consecutive needlings with 1 mL MMC0.2 mg/mL. At 24 months after surgery, the two eyes gave successful results without the need for any additional medical therapy, and with well-functioning conjunctival blebs. The PM was an effective alternative to the gold standard trabeculectomy in our severely myopic patient. A comparative study between conventional filtering operations and this MIBS in highly myopic patients would confirm our observation.


Asunto(s)
Glaucoma de Ángulo Abierto , Humanos , Femenino , Persona de Mediana Edad , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/diagnóstico , Trabeculectomía/métodos , Miopía/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Resultado del Tratamiento
12.
Jpn J Ophthalmol ; 68(3): 200-205, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38587787

RESUMEN

PURPOSE: To evaluate the surgical outcomes of intrascleral intraocular lens (IOL) fixation using ab interno trabeculotomy (LOT) in patients with exfoliation glaucoma with lens subluxation. STUDY DESIGN: Retrospective case series. METHODS: Twenty eyes of 18 patients with exfoliation glaucoma and lens or IOL subluxations were included. Three success criteria were based on postoperative intraocular pressure (IOP) (A, ≤15 mmHg; B, ≤18 mmHg; C, ≤21 mmHg). The IOP, number of glaucoma medications, and visual acuity were compared before and after surgery. Success probability was analyzed using Kaplan-Meier survival curves. Cox proportional hazards' regression models were used to examine prognostic factors for surgical failure. RESULTS: The mean follow-up period was 23.4 ± 7.8 months. The mean IOP significantly decreased from 23.2 ± 6.8 mmHg preoperatively to 14.0 ± 4.4 mmHg at 1 year postoperative (P<0.001). Postoperative hyphema and vitreous hemorrhage were observed in seven and 15 eyes, respectively, and washout in the anterior chamber or vitreous cavity was performed in four eyes. Postoperative IOP spikes and hypotony were observed in four eyes each. Glaucoma reoperation was performed in two eyes. The success rates at 12 months were 65%, 85%, and 90% using criteria A, B, and C, respectively. The IOP at 1 month after surgery was a significant prognostic factor for surgical failure according to criterion A (hazard ratio: 1.08; P=0.034). CONCLUSION: Intrascleral IOL fixation combined with microhook LOT is a promising option in cases of exfoliation glaucoma with subluxated lens/IOL; however, the high rate of postoperative hyphema and vitreous hemorrhage should be noted.


Asunto(s)
Síndrome de Exfoliación , Presión Intraocular , Implantación de Lentes Intraoculares , Subluxación del Cristalino , Esclerótica , Trabeculectomía , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Esclerótica/cirugía , Síndrome de Exfoliación/fisiopatología , Síndrome de Exfoliación/cirugía , Síndrome de Exfoliación/complicaciones , Trabeculectomía/métodos , Presión Intraocular/fisiología , Agudeza Visual/fisiología , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/fisiopatología , Subluxación del Cristalino/diagnóstico , Estudios de Seguimiento , Persona de Mediana Edad , Implantación de Lentes Intraoculares/métodos , Anciano de 80 o más Años , Lentes Intraoculares , Resultado del Tratamiento
13.
Trials ; 25(1): 287, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38679725

RESUMEN

BACKGROUND: Neovascular glaucoma (NVG) is an irreversible blinding eye disease worldwide and is classified as one of the refractory glaucoma conditions, severely impacting visual function and vision. Unfortunately, effective surgical interventions to improve the prognosis of NVG patients are currently lacking. The study aims to evaluate the efficacy and safety of anterior chamber proliferative membrane interception (AC-PMI)-enhanced trabeculectomy compared to the traditional trabeculectomy. METHODS: AC-PMI enhanced trabeculectomy versus trabeculectomy for the treatment of NVG is a single-center, prospective, double-arms, and randomized controlled trial of superior efficacy, which will involve 100 NVG inpatients. Patients will be randomly assigned into two groups using the random number table method. One group will undergo trabeculectomy using anti-vascular endothelial growth factor (Anti-VEGF) preoperatively and mitomycin C intraoperatively, while the other group will undergo AC-PMI enhanced trabeculectomy with the same medications (Anti-VEGF and mitomycin C). The patients will be followed up at the baseline and 1 day, 1 week, 1 month, 3 months, 6 months, 12 months, 18 months, and 24 months postoperatively. Meanwhile, we will collect the demographics, characteristics, and examination results and monitor any occurrences of adverse events at each follow-up time. DISCUSSION: This is an efficacy study of a novel surgical approach for treating neovascular glaucoma. Building upon conventional filtering surgeries, this approach introduces an additional step involving the interception of the proliferative membrane to effectively halt the growth of fibrovascular tissue. This study aims to explore a promising new surgical approach for managing NVG and contribute to the advancement of glaucoma treatment strategies. TRIAL REGISTRATION: ChiCTR ChiCTR2200055138. Registered on 01 January 2022. https://www.chictr.org.cn/showproj.html?proj=145255.


Asunto(s)
Glaucoma Neovascular , Ensayos Clínicos Controlados Aleatorios como Asunto , Trabeculectomía , Factor A de Crecimiento Endotelial Vascular , Humanos , Trabeculectomía/métodos , Trabeculectomía/efectos adversos , Glaucoma Neovascular/cirugía , Glaucoma Neovascular/fisiopatología , Estudios Prospectivos , Resultado del Tratamiento , Persona de Mediana Edad , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Anciano , Femenino , Masculino , Adulto , Cámara Anterior/cirugía , Presión Intraocular , Mitomicina/uso terapéutico , Mitomicina/administración & dosificación , Inhibidores de la Angiogénesis/uso terapéutico , Inhibidores de la Angiogénesis/administración & dosificación , Adulto Joven
14.
Ophthalmologie ; 121(5): 427-437, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38683364

RESUMEN

Excessive wound healing in filtering glaucoma surgery is a key factor for a failed surgery. After the introduction of trabeculectomy in the 1960s many factors associated with an increased fibrotic reaction were recognized and methods were developed to influence postoperative wound healing. These range from the perioperative use of anti-inflammatory drugs and antimetabolites to the use of newer chemical compounds that influence the morphology of postoperative fibroblast growth. In the routine clinical practice, the fine tuning of therapeutic decisions plays a decisive role in the success or failure of filtration surgery.


Asunto(s)
Glaucoma , Cuidados Posoperatorios , Trabeculectomía , Cicatrización de Heridas , Trabeculectomía/métodos , Humanos , Cicatrización de Heridas/efectos de los fármacos , Glaucoma/cirugía , Cuidados Posoperatorios/métodos , Antiinflamatorios/uso terapéutico , Complicaciones Posoperatorias
15.
Nagoya J Med Sci ; 86(1): 36-42, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38505714

RESUMEN

There are numerous surgical procedures for glaucoma. Minimally invasive glaucoma surgery is becoming popular; however, the disadvantage is the high incidence of anterior chamber hemorrhage. Heavy bleeding can also lead to increased intraocular pressure (IOP) postoperatively. Gonio scratch is a surgical procedure that improves aqueous humor outflow by rubbing off deposits on the trabecular meshwork with a Diamond Dusted Sweeper. As the conjunctiva and trabecular meshwork are not incised, no postoperative bleeding is expected, and the IOP spike will be minimal. We designed this study to determine the efficacy and safety of gonio scratch. This is an on-going multicenter, prospective, clinical trial. Patients who are scheduled for glaucoma surgery with or without cataract surgery are being enrolled. A total of 80 eyes will be recruited in the Hiroshima University Hospital, Miyoshi Eye Clinic, Yokoyama Retina Clinic, and Kusatsu Eye Clinic. All patients will undergo gonio scratch. When combined with cataract surgery, gonio scratch is performed after the intraocular lens is inserted. The primary study endpoint is the change in IOP from baseline to 1 year after surgery. The secondary endpoints are complications, number of glaucoma medications, surgical time, and changes in visual acuity and the visual field. This study protocol was approved by the institutional review board of Hiroshima University. The trial results will be shared with the scientific community at international conferences and by publication in a peer-reviewed journal. Trial registration number is jRCTs062200003.


Asunto(s)
Catarata , Glaucoma , Trabeculectomía , Humanos , Trabeculectomía/métodos , Estudios Prospectivos , Presión Intraocular , Glaucoma/cirugía , Glaucoma/complicaciones , Catarata/complicaciones , Resultado del Tratamiento
16.
J Glaucoma ; 33(4): 270-276, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38506849

RESUMEN

PRCIS: Large amount of trabeculotomy with Kahook Dual Blade (KDB) confers better intraocular pressure (IOP) lowering. PURPOSE: We compared the postoperative outcomes of trabeculotomy using the KDB in patients with exfoliation glaucoma (EXG) and primary open angle glaucoma between the 120-degree incision and the 210- to 240-degree incision groups. PATIENTS AND METHODS: We retrospectively analyzed the postoperative outcomes of trabeculotomy performed using the KDB in 101 eyes with EXG and primary open angle glaucoma, who received 120- and 210- to 240-degree incisions at Kumamoto University Hospital between April 25, 2018, and August 11, 2021. Kaplan-Meyer survival curves were used to assess the outcomes. Surgical failure was defined as IOP ≥21 mm Hg (criterion A) and ≥19 mm Hg (criterion B), or an IOP ≤4 mm Hg in either criterion and the need for additional glaucoma surgery. RESULTS: In total, 64 and 37 eyes were included in the 120 and 210- to 240-degree groups, respectively. The 210- to 240-degree group had a higher 1-year success rate compared with the 120-degree group, both when considering all eyes and when considering only those with EXG (P<0.05). CONCLUSIONS: In trabeculotomy with KDB, a 210- to 240-degree incision was more effective than a 120-degree incision in lowering IOP in EXG cases.


Asunto(s)
Síndrome de Exfoliación , Glaucoma de Ángulo Abierto , Trabeculectomía , Humanos , Síndrome de Exfoliación/cirugía , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/cirugía , Estudios Retrospectivos , Presión Intraocular
17.
Int Ophthalmol ; 44(1): 150, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38503938

RESUMEN

PURPOSE: To assess and compare the risk for development of cystoid macula edema (CME) after glaucoma drainage device (GDD) implantation versus conventional trabeculectomy with mitomycin (trab) for glaucoma. METHODS: Retrospective review of consecutive patients receiving trab or GDD implantation between 2016 and 2018. Inclusion criteria were availability of pre- and postoperative spectral domain optical coherence tomography (SD-OCT) of the macula. SD-OCT images were evaluated for presence of CME qualitatively, central subfield thickness (CST) and macular volume (MV). RESULTS: 73 eyes could be included, 42 received trab and 31 GDD surgery. Eyes receiving trab on average had 0.8 ± 0.8 previous intraocular operations, while eyes with GDD implantation had 3.1 ± 1.9 (p < 0.001). Occurrence of postoperative CME was significantly more frequent after GDD implantation (6 out of 31 (19.4%)) than after trab (2 out of 42 eyes = 4.8%), (p = 0.049). Mean preoperative CST as well as MV was comparable in both groups (CST before trab: 282.7 ± 23.0 µm, CST before GDD 284.2 ± 27.3 µm, p = 0.287; MV before trab: 7.8 ± 1.1 mm3, MV before GDD: 8.0 ± 0.8mm3, p = 0.305). Mean postoperative CST and MV were significantly higher after GDD (CST 338.5 ± 129.3 µm, MV 8.8 ± 2.6 mm3) than after trabeculectomy (CST 290.6 ± 60.2 µm, p = 0.038; MV 7.8 ± 1.2mm3, p = 0.039). CONCLUSIONS: In real-life conditions, GDD surgery seems to be associated with a higher risk to develop CME when compared to conventional trabeculectomy. This information may be helpful for glaucoma surgeons to advise the patients on postoperative risks of surgery.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Edema Macular , Trabeculectomía , Humanos , Trabeculectomía/efectos adversos , Trabeculectomía/métodos , Presión Intraocular , Glaucoma/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos , Edema Macular/diagnóstico , Edema Macular/etiología , Edema Macular/cirugía , Edema , Estudios Retrospectivos
18.
Arq Bras Oftalmol ; 87(3): e20230033, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537046

RESUMEN

PURPOSE: This study aims to compare the initial ocular discomfort symptoms resulting from trabeculectomy and Ahmed glaucoma valve implantation surgeries. METHODS: A prospective comparative study was conducted. The evaluation of ocular discomfort employed a questionnaire designed to identify the frequency and severity of distinct symptoms: ocular pain, general discomfort, tearing, foreign body sensation, and burning. This questionnaire was administered prior to surgery as a baseline, and subsequently at 7, 30, and 90 days post-surgery. Simultaneously, the Ocular Surface Disease Index (OSDI) was applied at these same time intervals. RESULTS: The study encompassed a total of 17 patients (9 undergoing trabeculectomy and 8 undergoing Ahmed glaucoma valve implantation). The Ahmed glaucoma valve implantation group exhibited higher tearing levels at baseline (p=0.038). However, no statistically significant differences in symptoms were observed between the two surgeries at 7 and 30 days post-surgery. At the 90-day mark following surgery, patients who had undergone trabeculectomy reported a significantly higher foreign body sensation (p=0.004). Although OSDI scores did not differ between groups at baseline, the trabeculectomy group showed significantly higher OSDI scores than the Ahmed glaucoma valve implantation group at 7, 30, and 90 days after surgery (p<0.05). CONCLUSION: Post-surgery, patients who had undergone trabeculectomy experienced increased foreign body sensation. Trabeculectomy appears to cause greater early postoperative ocular discomfort compared to the Ahmed glaucoma valve implantation group.


Asunto(s)
Cuerpos Extraños , Implantes de Drenaje de Glaucoma , Glaucoma , Trabeculectomía , Humanos , Trabeculectomía/efectos adversos , Estudios Prospectivos , Presión Intraocular , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma/etiología , Implantación de Prótesis/efectos adversos , Cuerpos Extraños/complicaciones , Cuerpos Extraños/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
19.
Arq Bras Oftalmol ; 87(2): e20220046, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38451677

RESUMEN

The creation of a scleral flap during trabeculectomy can be complicated by a buttonhole, partial amputation at the limbus, and extensive thinning. In some cases, the procedure must be aborted to prevent more serious postoperative complications. This report describes a technique of converting complicated trabeculectomy into ab externo cyclodialysis. A 41-year-old patient with congenital glaucoma presented with a perforated scleral wall with the choroidal tissue exposed during the dissection of the partial-thickness scleral flap. By using a Barraquer cyclodialysis spatula through the scleral perforation, the choroid was separated from the sclera up to the scleral spur over 30° into the anterior chamber. The sclera and conjunctiva/Tenon were sutured with 10-0 nylon single sutures. Two months later, the intraocular pressure was reduced to 16 mmHg with no hypotensive topical medications. This case illustrates an alternative approach to managing a flap-related perioperative complication in trabeculectomy, which yielded good early results.


Asunto(s)
Glaucoma , Trabeculectomía , Humanos , Adulto , Trabeculectomía/efectos adversos , Esclerótica/cirugía , Cámara Anterior , Conjuntiva/cirugía , Antihipertensivos , Glaucoma/cirugía
20.
BMC Ophthalmol ; 24(1): 108, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38448910

RESUMEN

BACKGROUND: To compare the bleb morphologies of phacoemulsification combined with Ex-PRESS implantation (Phaco-ExPRESS), phaco trabeculectomy (Phaco-Trab), and trabeculectomy (Trab) in postoperative two years. METHODS: Patients with primary open-angle glaucoma (POAG) with or without cataracts were included in this study. All patients underwent surgeries of either Phaco-ExPRESS, Phaco-Trab, or Trab. The morphologic structures of the filtering bleb, including microcysts area, hyperreflective dot density, and stromal connective tissue under in vivo confocal microscope (IVCM), were compared between the three groups. The data were collected preoperatively and postoperatively at 2 weeks, 1 month, 3 months, 6 months, 12 months, 18 months, and 24 months. RESULTS: Eighty-nine eyes from 89 patients were enrolled, including 32 in the Phaco-ExPRESS group, 25 in the Phaco-Trab group, and 32 in the Trab group. In a 24-month follow-up, bleb morphologies in Phaco-ExPRESS were similar to the Trab group. The area of epithelial microcysts was significantly increased in Phaco-ExPRESS and Trab groups while significantly decreased in Phaco-Trab. At postoperative 24 months, the complete success rate was 65.1% in Phaco-ExPRESS, 32.0% in Phaco-Trab, and 59.4% in the Trab group (P = 0.03). The phaco-Trab group had more postoperative anti-glaucoma medications than the other two groups (P < 0.05). CONCLUSIONS: Phaco-ExPRESS group and Trab group had similar blebs morphologies in IVCM, with larger microcyst area, looser connective tissue, and less inflammation than Phaco-Trab, indicating that the function of blebs in the Phaco-ExPRESS and Trab group, was more potent than that of Phaco-Trab. All these surgical methods provided adequate IOP control, but Phaco-Trab required more anti-glaucoma medications.


Asunto(s)
Quistes , Glaucoma de Ángulo Abierto , Facoemulsificación , Trabeculectomía , Humanos , Agentes Antiglaucoma , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Estudios Retrospectivos , Microscopía Confocal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA